Awarded Contract

Information

Published

Date of dispatch of this notice: 14/03/2023

External Reference: 660fc91a-10ef-4c01-a2be-768b537d4598

Awarded Contract

Cached Version

Preliminary Data

Type of contract: Products
Procedure: Open
Awarded Procedure Type: Open

Contact information

Official name: United Kingdom Atomic Energy Authority
Url: www.gov.uk/government/organisations/uk-atomic-energy-authority
Address line 1: Culham Science Centre
Town: Abingdon
Postal Code: OX14 3DB
Country: England
Contact person: Ben Oborne
E-mail: ben.oborne@ukaea.uk
Phone: +44 1235467082

Contract information

Title attributed to the contract: H3AT TMC Metal Bellow Pump
Description:

The objective of Tritium Monitoring and Counting (TMC) project is to design, build and operate a test rig that will allow different on-line gas composition analysers to be tested under some of operating conditions that would be found in the DEMO plant. The intention of this work is to develop a tritium analytics experiment to support the DEMO tritium accountancy concept, namely, to provide improved knowledge on critical measurement techniques so that the associated uncertainty of the DEMO accountancy statement is reduced. Achieving this is prerequisite to satisfying the regulatory requirements pertaining to safety, the environment and non-proliferation for which the need to know how much tritium there is and where the tritium is in the fuel cycle at all times is key. A further requirement is the ability to measure tritium to satisfy the needs for process monitoring and control (PMC).

To this end, four operating conditions have been identified: static, continuous, recirculation and response rate. The first phase of this project (Romanelli, 2021) showed that Raman and Mass Spectrometry are highly advanced in technical readiness for tritium measurements in DEMO. Therefore, Raman Spectrometry will be tested as a continuous measurement technique with Mass Spectrometry used as a reference technique.

The TMC experimental rig is intended for gas analysis using a reference analyser and analytical analysers. The mass spectrometer has been chosen as the reference analyser while the Raman spectrometer is the analytical analyser. There is also the potential for using a second analytical analyser. Gas samples will be analysed using these analysers in different operational modes. The analysed gases will then be evacuated to a suitable location.

Among the several required components for the TMC rig, there are different types of pumps.  Object of the present tender is a metal bellow pump.

Common procurement vocabulary (CPV)
31681200   Electric pumps
42122000   Pumps
42122450   Vacuum pumps

Dates
Expire date: 13/01/2023 12:00
Contract start date: 27/01/2023
Contract end date: 31/03/2023

Values
Lowest value: 30000
Highest value: 40000

Complementary information

Is this suitable for SME (Small and Medium Enterprises)?:
Is this suitable for VCSE (Voluntary Community and Social Enterprise)?:

Region(s)
South East

Additional Details

Attachment 0
https://uk.eu-supply.com/app/rfq/rwlentrance_s.asp?PID=58176&B=UKAEA

Additional data
Attachment 1
https://uk.eu-supply.com/ctm/Company/CompanyInformation/Index/72814

User / Company

Award Information

Awarded Date: 15/02/2023
Awarded Value: 16,300.00
Contract start date: 07/03/2023
Contract end date: 29/09/2023

Supplier Information 0
Supplier's name:
IBS Inc.
Supplier's address:
12-43 Honami-cho Suita Osaka Japan 564-0042
Contact person:
DUNS number of supplier:
Additional information:

AnnexD